Adit 600 - Release 10.1.1 29
Quick Start
Configuration
E1 Setup
NOTE: E1 is not supported in this release of the Adit 600 Controller. It will be
supported in a future release.
Use the following commands to set up an E1. See the set (e1) command for more
details.
DS0/Channel Setup
Use the following commands to set up a DS0. See the set (ds0) command for details.
Command Description
set {e1-addr} up Activate the port of the E1 (slot:port)
set {e1-addr} id {"id-string"} Set the identification string
set {e1-addr} lbo {1 - 9} Set the line buildout value for the E1
set {e1-addr} linecode
{ami|hdb3}
Set the linecode for the E1
set {e1-addr} framing
{e1fr|lefrcrc}
Set the framing option for the E1
set {e1-addr} loopdetect
{on|off}
Set the detection/reaction to CSU loopcodes
Command Description
set {slot:port:channel} up Activate the channel.
set {slot:port:channel} signal
{ls|gs|emw|emdw|emicpd|dpt}
Set the signaling option for the channel.
set {slot:port:channel} type
{data|voice}
Set the channel type.