Access Bank II SDSL Product Guide
Access Bank II/SDSL/RPM Single T1 voice and data multiplexer/channel bank/small-line digital loop carrier and CSU/DSU supporting
12 or 24 analog lines, one SDSL interface for data connectivity, one V.35 interface, one RS-232
synchronous/asynchronous interface, Windows 95-based GUI management and RPM included.
Access Bank II/SDSL/SNMP/RPM Single T1 voice and data multiplexer/channel bank/small-line digital loop carrier and CSU/DSU supporting
12 or 24 analog lines, one SDSL interface for data connectivity, one V.35 interface, one RS-232
synchronous/asynchronous interface, command line interface- (CLI), SNMP/Telnet via 10BaseT Ethernet,
Windows 95-based GUI management, & RPM included.
Item Part Number Description
Configured Systems
RPM MANAGEMENT
Access Bank II SDSL/RPM with AB-115 Power for AC Conversion
ABII SDSL/RPM Base w/AC Cube 900-0150 ABII chassis, 1 T1, 1 SDSL port, nodal controller, V.35, RPM, AC converter
ABII SDSL/RPM FXS w/AC Cube 900-0151 ABII chassis, 1 T1, 1 SDSL port, nodal controller, V.35, RPM, AC converter, 12 FXS
ABII SDSL/RPM FXS/FXS w/AC Cube 900-0152 ABII chassis, 1 T1, 1 SDSL port, nodal controller, V.35, RPM, AC converter, 24 FXS
ABII SDSL/RPM FXO w/AC Cube 900-0153 ABII chassis, 1 T1, 1 SDSL port, nodal controller, V.35, RPM, AC converter, 12 FXO
ABII SDSL/RPM FXO/FXO w/AC Cube 900-0154 ABII chassis, 1 T1, 1 SDSL port, nodal controller, V.35, RPM, AC converter, 24 FXO
ABII SDSL/RPM 4FXO/8FXS w/AC Cube 900-0156 ABII chassis, 1 T1, 1 SDSL port, nodal controller, V.35, RPM, AC converter, 4 FXO, 8 FXS
ABII SDSL/RPM 8FXO/16FXS w/AC Cube 900-0157 ABII chassis, 1 T1, 1 SDSL port, nodal controller, V.35, RPM, AC converter, 8 FXO, 16 FXS
ABII SDSL/RPM 4FXO/20FXS w/AC Cube 900-0158 ABII chassis, 1 T1, 1 SDSL port, nodal controller, V.35, RPM, AC converter, 4 FXO, 20 FXS
Access Bank II SDSL/RPM with 115 Charger, 50W for Carrier Access Battery Unit
ABII SDSL/RPM Base w/Charger 910-0150 ABII chassis, 1 T1, 1 SDSL port, nodal controller, V.35, RPM, AC converter/battery charger
ABII SDSL/RPM FXS w/Charger 910-0151 ABII chassis, 1 T1, 1 SDSL port, nodal controller, V.35, RPM, AC converter/battery charger, 12 FXS
ABII SDSL/RPM FXS/FXS w/Charger 910-0152 ABII chassis, 1 T1, 1 SDSL port, nodal controller, V.35, RPM, AC converter/battery charger, 24 FXS
ABII SDSL/RPM FXO w/Charger 910-0153 ABII chassis, 1 T1, 1 SDSL port, nodal controller, V.35, RPM, AC converter/battery charger, 12 FXO
ABII SDSL/RPM FXO/FXO w/Charger 910-0154 ABII chassis, 1 T1, 1 SDSL port, nodal controller, V.35, RPM, AC converter/battery charger, 24 FXO
ABII SDSL/RPM 4FXO/8FXS w/Charger 910-0156 ABII chassis, 1 T1, 1 SDSL port, nodal controller, V.35, RPM, AC converter/battery charger, 4 FXO, 8 FXS
ABII SDSL/RPM 8FXO/16FXS w/Charger 910-0157 ABII chassis, 1 T1, 1 SDSL port, nodal controller, V.35, RPM, AC converter/battery charger, 8 FXO, 16 FXS
ABII SDSL/RPM 4FXO/20FXS w/Charger 910-0158 ABII chassis, 1 T1, 1 SDSL port, nodal controller, V.35, RPM, AC converter/battery charger, 4 FXO, 20 FXS
Access Bank II SDSL/RPM without Power Conversion for Direct -48 VDC Input
ABII SDSL/RPM Base w/No Power 930-0150 ABII chassis, 1 T1, 1 SDSL port, nodal controller, V.35, RPM, -48 VDC input
Form # CF-118, Rev. C
Carrier Access
Page 1
Part-03-001
Updated 09/18/00
Commentaires sur ces manuels