5-236 Axxius 800 - Release 2.2
CLI Commands
status
status (ds3) performance
Use the status (ds3) performance command to display the performance statistics for the
current (15 min) and previous (15 min, hour and day) information of a DS3.
Syntax: status {ds3-addr} performance
> status a:1 performance
SLOT A:
Performance Statistics for DS3 Port 1:
Near End Statistics:
current previous
15 min.
15 min. 1 hour 1 d a y
unavailable seconds: 0 0 0 0
sev. errored frame seconds: 0 0 0 0
sev. errored c-bit seconds: 0 0 0 0
errored c-bit seconds: 0 0 0 0
sev. errored p-bit seconds: 0 0 0 0
p-bit errored seconds: 0 0 0 0
line errored seconds: 0 0 0 0
total linecode violations: 0 0 0 0
total pathcode violations: 0 0 0 0
total cbitcode violations: 0 0 0 0
Far End Statistics:
unavailable seconds: 0 0 0
sev. errored c-bit seconds: 0 0 0
errored c-bit seconds: 0 0 0
total cbitcode violations: 0 0 0
elapsed time in current 15 min. interval: 4:24
valid 15 min. intervals in hour: 3
valid 15 min. intervals in Day: 3
* - indicates threshold has been crossed.
{ds3-addr}
In the form of {slot port}:
slot A, with a DS3 controller card installed.
port Port number or range. Range of ports is 1-2