10-6 Axxius 800 - Release 2.2
OCU-DP Card
Technical Specifications
Network Interface
l Each OCU port DS0 cross-connected to T1 port
Loopbacks
OCU, CSU and DSU:
l Manual loopbacks activate via CLI
l Non-latching loopbacks activate via network code
l Latching loopbacks activate via network code
Clocking
l Loop-timed from any T1 in the platform
l Sources clock to the DTE device
Power Consumption
l 6 W maximum, Quad-Port OCU-DP card
l 3 W maximum, Single-Port OCU-DP card
Environment
In addition to the systems environment requirements, the following applies to the
OCU-DP card. For additional information see Installation Environment on page 2-3.
l Operating temperature range: 32° to 104° F (0° to 40° C)
Physical
l Dimensions: 3.5 in. (H) x 0.75 in. (W) x 11.25 in. (D)
8.9 cm (H) x 1.9 cm (W) x 28.6 cm (D)
l Weight: 5.7 oz. (0.16 kg)