Axxius 800 - Release 2.2 12-3
Power Supply
Technical Specifications
Technical Specifications
Components
l 24 VDC Power Supply
l 48 VDC NI48 Power Supply
l 48 VDC I48 Power Supply
l Cable connector
Electrical Input Characteristics
Input power fully isolated from circuit and chassis ground
24 VDC
l 24 (21.0 to 30.0) VDC, +5 ADC, 120 W rated input
l Startup at 22 V maximum
l Low voltage shutdown at 19 V minimum
l High voltage shutdown at 33 V minimum
l Maximum cold start inrush current: 15 A peak at 30 VDC
48 VDC
l 48 (41.0 to 60.0) VDC, 2.5 ADC, 120 W rated input
l Startup at 44 V maximum
l Low voltage shutdown at 37.5 V minimum
l High voltage shutdown at 66.0 V minimum
l Maximum cold start inrush current: 7.5 A peak at 60 VDC
Electrical Output Characteristics
l 5 VDC, 20 A maximum