4-2 Axxius 800 - Release 2.2
Configuration
Setting up a CLI Connection
Setting up a CLI Connection
NOTE: The Default IP address of the Axxius 800 Controller (DS1 or DS3)
is 10.0.0.10.
To connect to the CLI, set up the connection:
l If connecting via the ethernet 10Base-T connection, use a Telnet TCP/IP
program to access the CLI. This requires an IP address of the Controller. The
Controllers are shipped with the IP address set to 10.0.0.10, if this address has
been changed and is not known, use HyperTerm to access the Controller and
use the CLI command show ip. If an IP address needs to be set use the CLI
command set ethernet ip address {ip-addr}.
l If connecting via RS-232 (HyperTerm), the port settings should be set to:
Bits per second: 9600
Data bits: 8
Parity: None
Stop bits: 1
Flow control: None
l
Set your Terminal Emulation to: VT100
NOTE: Note: When using Tera Term TCP/IP, CLI commands will not be
recognized until the following setup is completed.
l In Tera Term go to Setup/Terminal.
l Set the New-line/Transmit value "CR+LF".
Vue de la page 73
1 2 ... 69 70 71 72 73 74 75 76 77 78 79 ... 567 568