Carrier Access Network Device Axxius 800 Manuel d'utilisateur Page 14

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 52
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 13
16 Axxius 800 - Release 2.2
Quick Start
Chassis Connections
Chassis Ground Connector
1. Route wire (#6 or #8 AWG copper) from building ground to lug on Axxius
800.
2. Strip insulation off wire end, if necessary.
3. Loosen compression screw until opening is large enough to accept ground
wire.
4. Insert ground wire into lug barrel, beneath compression plate and tighten
compression screw.
5. Attach ground lug to chassis
Ground Terminals
Ground Lug
Compression
Screw
Lug Barrel
Vue de la page 13
1 2 ... 9 10 11 12 13 14 15 16 17 18 19 ... 51 52

Commentaires sur ces manuels

Pas de commentaire